| PERFORMANCE |
| Voltage: |
nominal 12/24V |
| Voltage: |
operating 12/24V |
| Signal Source: |
Engine Electronic Control Module (ECM) |
| VIBRATION |
| Operating: |
0.5G
|
| Storage: |
50G
|
| TRANSIENT
VOLTAGE |
| Withstands
voltage transients of 200 Volts for 300 microseconds duration (SAE
J1810) |
| OVER VOLTAGE
PROTECTION |
| Tested with a supply voltage
for 20 Volts for 1 hour. |
| Reverse polarity protected. |
| CORROSIVE
GAS |
| NOT ACCEPTABLE. |
|
TEMPERATURE
Tested at the following operating ranges:
|
| A. If being used as a rear
engine run box |
Operating: |
-4°F to 158°F
|
| Storage: |
-22°F
to -176°F
|
| (-30°C to
80°C) |
| B. For use as a diagnostic
tool |
Operating: |
32°F
to 122°F
|
| Storage: |
-4°F
to 158°F
|
| (-20°C to
70°C) |
| SHOCK |
| Operating: |
3G
|
| Storage: |
50G
|
| LOAD
DUMP |
| Meets (SAE
J113) three positive 80 Volt transients with one minute intervals. |
| SALT
SPRAY |
| NOT ACCEPTABLE. |
|